enum_mac80211_tx_info_flags(9) flags to describe transmission information/status

SYNOPSIS


enum mac80211_tx_info_flags {
IEEE80211_TX_CTL_REQ_TX_STATUS,
IEEE80211_TX_CTL_ASSIGN_SEQ,
IEEE80211_TX_CTL_NO_ACK,
IEEE80211_TX_CTL_CLEAR_PS_FILT,
IEEE80211_TX_CTL_FIRST_FRAGMENT,
IEEE80211_TX_CTL_SEND_AFTER_DTIM,
IEEE80211_TX_CTL_AMPDU,
IEEE80211_TX_CTL_INJECTED,
IEEE80211_TX_STAT_TX_FILTERED,
IEEE80211_TX_STAT_ACK,
IEEE80211_TX_STAT_AMPDU,
IEEE80211_TX_STAT_AMPDU_NO_BACK,
IEEE80211_TX_CTL_RATE_CTRL_PROBE,
IEEE80211_TX_INTFL_OFFCHAN_TX_OK,
IEEE80211_TX_INTFL_NEED_TXPROCESSING,
IEEE80211_TX_INTFL_RETRIED,
IEEE80211_TX_INTFL_DONT_ENCRYPT,
IEEE80211_TX_CTL_NO_PS_BUFFER,
IEEE80211_TX_CTL_MORE_FRAMES,
IEEE80211_TX_INTFL_RETRANSMISSION,
IEEE80211_TX_INTFL_MLME_CONN_TX,
IEEE80211_TX_INTFL_NL80211_FRAME_TX,
IEEE80211_TX_CTL_LDPC,
IEEE80211_TX_CTL_STBC,
IEEE80211_TX_CTL_TX_OFFCHAN,
IEEE80211_TX_INTFL_TKIP_MIC_FAILURE,
IEEE80211_TX_CTL_NO_CCK_RATE,
IEEE80211_TX_STATUS_EOSP,
IEEE80211_TX_CTL_USE_MINRATE,
IEEE80211_TX_CTL_DONTFRAG,
IEEE80211_TX_CTL_PS_RESPONSE
};

CONSTANTS

IEEE80211_TX_CTL_REQ_TX_STATUS

require TX status callback for this frame.

IEEE80211_TX_CTL_ASSIGN_SEQ

The driver has to assign a sequence number to this frame, taking care of not overwriting the fragment number and increasing the sequence number only when the IEEE80211_TX_CTL_FIRST_FRAGMENT flag is set. mac80211 will properly assign sequence numbers to QoS-data frames but cannot do so correctly for non-QoS-data and management frames because beacons need them from that counter as well and mac80211 cannot guarantee proper sequencing. If this flag is set, the driver should instruct the hardware to assign a sequence number to the frame or assign one itself. Cf. IEEE 802.11-2007 7.1.3.4.1 paragraph 3. This flag will always be set for beacons and always be clear for frames without a sequence number field.

IEEE80211_TX_CTL_NO_ACK

tell the low level not to wait for an ack

IEEE80211_TX_CTL_CLEAR_PS_FILT

clear powersave filter for destination station

IEEE80211_TX_CTL_FIRST_FRAGMENT

this is a first fragment of the frame

IEEE80211_TX_CTL_SEND_AFTER_DTIM

send this frame after DTIM beacon

IEEE80211_TX_CTL_AMPDU

this frame should be sent as part of an A-MPDU

IEEE80211_TX_CTL_INJECTED

Frame was injected, internal to mac80211.

IEEE80211_TX_STAT_TX_FILTERED

The frame was not transmitted because the destination STA was in powersave mode. Note that to avoid race conditions, the filter must be set by the hardware or firmware upon receiving a frame that indicates that the station went to sleep (must be done on device to filter frames already on the queue) and may only be unset after mac80211 gives the OK for that by setting the IEEE80211_TX_CTL_CLEAR_PS_FILT (see above), since only then is it guaranteed that no more frames are in the hardware queue.

IEEE80211_TX_STAT_ACK

Frame was acknowledged

IEEE80211_TX_STAT_AMPDU

The frame was aggregated, so status is for the whole aggregation.

IEEE80211_TX_STAT_AMPDU_NO_BACK

no block ack was returned, so consider using block ack request (BAR).

IEEE80211_TX_CTL_RATE_CTRL_PROBE

internal to mac80211, can be set by rate control algorithms to indicate probe rate, will be cleared for fragmented frames (except on the last fragment)

IEEE80211_TX_INTFL_OFFCHAN_TX_OK

Internal to mac80211. Used to indicate that a frame can be transmitted while the queues are stopped for off-channel operation.

IEEE80211_TX_INTFL_NEED_TXPROCESSING

completely internal to mac80211, used to indicate that a pending frame requires TX processing before it can be sent out.

IEEE80211_TX_INTFL_RETRIED

completely internal to mac80211, used to indicate that a frame was already retried due to PS

IEEE80211_TX_INTFL_DONT_ENCRYPT

completely internal to mac80211, used to indicate frame should not be encrypted

IEEE80211_TX_CTL_NO_PS_BUFFER

This frame is a response to a poll frame (PS-Poll or uAPSD) or a non-bufferable MMPDU and must be sent although the station is in powersave mode.

IEEE80211_TX_CTL_MORE_FRAMES

More frames will be passed to the transmit function after the current frame, this can be used by drivers to kick the DMA queue only if unset or when the queue gets full.

IEEE80211_TX_INTFL_RETRANSMISSION

This frame is being retransmitted after TX status because the destination was asleep, it must not be modified again (no seqno assignment, crypto, etc.)

IEEE80211_TX_INTFL_MLME_CONN_TX

This frame was transmitted by the MLME code for connection establishment, this indicates that its status should kick the MLME state machine.

IEEE80211_TX_INTFL_NL80211_FRAME_TX

Frame was requested through nl80211 MLME command (internal to mac80211 to figure out whether to send TX status to user space)

IEEE80211_TX_CTL_LDPC

tells the driver to use LDPC for this frame

IEEE80211_TX_CTL_STBC

Enables Space-Time Block Coding (STBC) for this frame and selects the maximum number of streams that it can use.

IEEE80211_TX_CTL_TX_OFFCHAN

Marks this packet to be transmitted on the off-channel channel when a remain-on-channel offload is done in hardware -- normal packets still flow and are expected to be handled properly by the device.

IEEE80211_TX_INTFL_TKIP_MIC_FAILURE

Marks this packet to be used for TKIP testing. It will be sent out with incorrect Michael MIC key to allow TKIP countermeasures to be tested.

IEEE80211_TX_CTL_NO_CCK_RATE

This frame will be sent at non CCK rate. This flag is actually used for management frame especially for P2P frames not being sent at CCK rate in 2GHz band.

IEEE80211_TX_STATUS_EOSP

This packet marks the end of service period, when its status is reported the service period ends. For frames in an SP that mac80211 transmits, it is already set; for driver frames the driver may set this flag. It is also used to do the same for PS-Poll responses.

IEEE80211_TX_CTL_USE_MINRATE

This frame will be sent at lowest rate. This flag is used to send nullfunc frame at minimum rate when the nullfunc is used for connection monitoring purpose.

IEEE80211_TX_CTL_DONTFRAG

Don't fragment this packet even if it would be fragmented by size (this is optional, only used for monitor injection).

IEEE80211_TX_CTL_PS_RESPONSE

This frame is a response to a poll frame (PS-Poll or uAPSD).

DESCRIPTION

These flags are used with the flags member of ieee80211_tx_info.

NOTE

If you have to add new flags to the enumeration, then don't forget to update IEEE80211_TX_TEMPORARY_FLAGS when necessary.

AUTHOR

Johannes Berg <[email protected]>

Author.

COPYRIGHT