SYNOPSIS
hpialarms [-D id] [-N host[:port]] [-C <cfgfile>]
[-a 1|0][-b 1|0][-c 1|0][-m 1|0][-n 1|0][-p 1|0][-i n][-o][-X][-h]
hpialarms [--domain=id] [--host=host[:port]] [--cfgfile=file]
[--diska=1|0] [--diskb=1|0] [--critical=1|0] [--major=1|0]
[--minor=1|0] [--power=1|0] [--chassisid=n] [--all] [--debug] [--help]
DESCRIPTION
hpialarms walks the RPT (Resource Presence Table) for resources that have ``Alarm Control'' management instruments (SAHPI_CTRL_LED).If no domain or host is selected, hpialarms uses the default domain as specified in the openhpiclient.conf file.
OPTIONS
(No Option) Display alarm statesHelp Options:
- -h, --help
- Show help options
Application Options:
- -c 1|0, --critical=1|0
- Set critical alarm on|off
- -m 1|0, --major=1|0
- Set major alarm on|off
- -n 1|0, --minor=1|0
- Set minor alarm on|off
- -a 1|0, --diska=1|0
- Set diska alarm on|off
- -b 1|0, --diskb=1|0
- Set diskb alarm on|off
- -p 1|0, --power=1|0
- Set power alarm on|off
- -i n, --chassisid=n
- Set chassis id on for n seconds
- -o, --all
- Set all alarms off
- -D nn, --domain=nn
- Select domain id nn
- -X, --debug
- Display debug messages
- -N "host[:port]", --host="host[:port]"
- Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and OPENHPI_DAEMON_PORT environment variables. If host contains ':' (for example IPv6 address) then enclose it in square brackets. For example: ``[::1]'' or ``[::1]:4743''.
- -C "file", --cfgfile="file"
- Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONF environment variable.
SAMPLE OUTPUT
hpialarmpanel ver 0.6 RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid=1 tag: Mullins RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON RDR[46]: ctltype=0:0 oem=0 Cold Reset Control RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
AUTHORS
Authors of this man page:
Peter D Phan ([email protected]) Ulrich Kleber ([email protected]) Anton Pak ([email protected])