Other Alias
mio_close, mio_read, mio_write, mio_nfds, mio_pollfd, mio_revents, mio_eofSYNOPSIS
In sndio.h Ft struct mio_hdl * Fn mio_open const char *name unsigned int mode int nbio_flag Ft void Fn mio_close struct mio_hdl *hdl Ft size_t Fn mio_read struct mio_hdl *hdl void *addr size_t nbytes Ft size_t Fn mio_write struct mio_hdl *hdl const void *addr size_t nbytes Ft int Fn mio_nfds struct mio_hdl *hdl Ft int Fn mio_pollfd struct mio_hdl *hdl struct pollfd *pfd int events Ft int Fn mio_revents struct mio_hdl *hdl struct pollfd *pfd Ft int Fn mio_eof struct mio_hdl *hdlDESCRIPTION
The sndio library allows user processes to access midi(4) hardware and sndiod(8) MIDI thru boxes and control ports in a uniform way.Opening and closing an MIDI stream
First the application must call the Fn mio_open function to obtain a handle representing the newly created stream; later it will be passed as the hdl argument of most other functions. The name parameter gives the device string discussed in sndio(7). If the program is using a single device and is providing no device chooser, it should be set to MIO_PORTANY to allow the user to select it using the MIDIDEVICE environment variable.The mode parameter gives the direction of the stream. The following are supported:
- MIO_OUT
- The stream is output-only; data written to the stream will be sent to the hardware or other programs.
- MIO_IN
- The stream is input-only; received data from the hardware or other programs must be read from the stream.
- MIO_IN | MIO_OUT
- The stream sends and receives data. This mode should be used rather than calling Fn mio_open twice.
If the nbio_flag argument is true (i.e. non-zero), then the Fn mio_read and Fn mio_write functions (see below) will be non-blocking.
The Fn mio_close function closes the stream and frees all allocated resources associated with the libsndio handle.
Sending and receiving data
When input mode is selected, the Fn mio_read function must be called to retrieve received data; it must be called often enough to ensure that internal buffers will not overrun. It will store at most nbytes bytes at the addr location. Unless the nbio_flag flag is set, it will block until data becomes available and will return zero only on error.When output mode is selected, the Fn mio_write function can be called to provide data to transmit. Unless the nbio_flag is set, Fn mio_write will block until the requested amount of data is written.
Non-blocking mode operation
If the nbio_flag is set on Fn mio_open , then the Fn mio_read and Fn mio_write functions will never block; if no data is available, they will return zero immediately.To avoid busy loops when non-blocking mode is used, the poll(2) system call can be used to check if data can be read from or written to the stream. The Fn mio_pollfd function prepares the array pfd of pollfd structures for use with poll(2). The optimal size of the pfd array, which the caller must pre-allocate, is provided by the Fn mio_nfds function.
poll(2) will sleep until any of the events requested with Fn mio_pollfd have occurred. Events are represented as a bit-mask of POLLIN and POLLOUT constants. The events which woke up poll(2) can be obtained with the Fn mio_revents function. If POLLIN is set, Fn mio_read can be called without blocking. If POLLOUT is set, Fn mio_write can be called without blocking. POLLHUP may be set if an error occurs, even if it is not requested with Fn mio_pollfd .
Error handling
Errors related to the MIDI subsystem (like hardware errors or dropped connections) and programming errors (such as a call to Fn mio_read on a play-only stream) are considered fatal. Once an error occurs, all functions which take a mio_hdl argument, except Fn mio_close and Fn mio_eof , stop working (i.e. always return 0).RETURN VALUES
The Fn mio_open function returns the newly created handle on success or NULL on failure.The Fn mio_pollfd function returns the number of pollfd structures filled. The Fn mio_nfds function returns the number of pollfd structures the caller must preallocate in order to be sure that Fn mio_pollfd will never overrun.
The Fn mio_revents function returns the bit-mask set by poll(2) in the pfd array of pollfd structures.
The Fn mio_read and Fn mio_write functions return the number of bytes transferred.
The Fn mio_eof function returns 0 if there's no pending error, and a non-zero value if there's an error.
ENVIRONMENT
- SNDIO_DEBUG
- The debug level: may be a value between 0 and 2.