SYNOPSIS
- int regulator_set_voltage_time_sel(struct regulator_dev * rdev, unsigned int old_selector, unsigned int new_selector);
ARGUMENTS
rdev
-
- regulator source device
old_selector
- selector for starting voltage
new_selector
- selector for target voltage
DESCRIPTION
Provided with the starting and target voltage selectors, this function returns time in microseconds required to rise or fall to this new voltage
Drivers providing ramp_delay in regulation_constraints can use this as their set_voltage_time_sel operation.
AUTHORS
Liam Girdwood <[email protected]>
- Author.
Mark Brown <[email protected]>
Wolfson Microelectronics,
- Author.
COPYRIGHT