tntnet.properties(7) configuration-file for tntnet (8)

DESCRIPTION

tntnet(8) uses cxxtools for logging and is configured in the configuration-file tntnet.properties.

Because cxxtools is a meta-logging-library, which can be compiled to use different logging-libraries, the content of tntnet.properties is dependend of the underlying logging-library. Cxxtool has a built-in logging-library as default, which is documented here.

format

The format of tntnet.properties is line-based. A line consists of a variable-name followed by a equals-symbol and a value. Lines, which does not follow this format and lines, which start with a hash (#), are ignored. It is recomended to prefix non-empty comments with a hash to make clear, that it is a comment.

level

The logging-library has 5 levels for logging: fatal, error, warn, info and debug. Fatal has the highers priority and "debug" the lowest.

category

Each log-message has a category. Categories are hierarchical. Names of subcategories are devided by a dot.

log-message

Each log-message has a level and a category. If the level of the message is higher or equal to the level of the category, the message is logged. To assign a level to a category put a line with the word "logger", a dot, the category, the symbol "=" and the category into tntnet.properties. Only the first letter of the value is checked and case is ignored, so e.g. info can be specified with INFO, info, I or even ixxxx. If no level is specified for the current category, the upper category is checked. If nothing is found, the default level is used. The default level is specified by the variable "rootLogger". If no rootLogger is specified, the level error is used.

destination

If nothing else is specified, log-messages are printed to standard-output. To redirect output to a file, specify the filename with the variable file.

The cxxtools-logger can limit the size of the log-file by rolling log-files. If the limit is reached, the current file is renamed by appending ".1" to it. If there is already a file with that name, this file is renamed to "*.2" and so on, until the maximum backupfile limit is reached. The oldest file is deleted then. To specify the maximum file size, set the variable maxfilesize. The value specified here can be postfixed with 'k' or 'M' to specify kBytes or MBytes. The maximum fileindex backed up is set with maxbackupindex.

Log-messages can be sent to another host in the network with udp. This is done by specifying a hostname and a port with the variable host. The value must be a hostname, followed by a ':' and a port. Each log-message is sent in a single udp-message.

EXAMPLES

logging to standard-output:

rootLogger=INFO
logger.tntnet=WARN

logging to a file with rolling file and a background-flusher:

rootLogger=INFO
logger.tntnet=WARN
file=tntnet.log
maxfilesize=1MB
maxbackupindex=10

logging to another host

rootLogger=INFO
logger.tntnet=WARN
host=pluto.tntnet.org:1234

AUTHOR

This manual page was written by Tommi Mäkitalo <[email protected]>.