watchdog.conf(5)
configuration file for the watchdog daemon
DESCRIPTION
This file carries all configuration options for the Linux watchdog daemon.
Each option has to be written on a line for itself. Comments start with '#'.
Blanks are ignored except after the '=' sign. An empty text after the '='
sign disables the feature as long as that makes sense.
OPTIONS
- interval = <interval>
-
Set the highest possible interval between two writes to the watchdog device.
The device is triggered after each check regardless of the time it took. After
finishing all checks watchdog goes to sleep for a full cycle of <interval>
seconds. Default value is 1 second. The kernel drivers expects a write command
every minute. Otherwise the system will be rebooted. Therefore an interval of
more than a minute can only be used with the force command-line option [--force | -f].
- logtick = <logtick>
-
If you enable verbose logging, a message is written into the syslog or a
logfile. While this is nice, it is not necessary to get a message every
interval which really fills up disk and needs CPU. logtick allows adjustment
of the number of intervals skipped before a log message is written. If you
use logtick = 60 and interval = 10, only every 10 minutes (600 seconds) a
message is written. This may make the exact time of a crash harder to find but
greatly reduces disk usage and administrator nerves if you're looking for a
particular syslog entry in between of watchdog messages.
- max-load-1 = <load1>
-
Set the maximal allowed load average for a 1 minute span. Once this load
average is reached the system is rebooted. Default value is 0. That means
the load average check is disabled. Be careful not to set this parameter too
low. To set a value less then the predefined minimal value of 2, you have to
use the -f command line option.
- max-load-5 = <load5>
-
Set the maximal allowed load average for a 5 minute span. Once this load
average is reached the system is rebooted. Default value is 3/4*max-load-1.
Be careful not to this parameter too low. To set a value less then the
predefined minimal value of 2, you have to use the -f command line option.
- max-load-15 = <load15>
-
Set the maximal allowed load average for a 15 minute span. Once this load
average is reached the system is rebooted. Default value is 1/2*max-load-1.
Be careful not to this parameter too low. To set a value less then the
predefined minimal value of 2, you have to use the -f command line option.
- min-memory = <minpage>
-
Set the minimal amount of virtual memory that has to stay free. Note that
this is in memory pages (4kB on x86). Default value is 0 pages which means
this test is disabled. The page size is taken from the system include files.
This is a 'passive' test and works by reading /proc/meminfo
- allocatable-memory = <minpage>
-
Set the minimum amount of allocatable memory available on the system.
Note that this is in pages. Default value is 0 pages which means the test
is disabled. As with min-memory, the page size is taken from the system
include files. This is an 'active' test and it works by attempting to
memory-map a block of the configured size.
- watchdog-device = <device>
-
Set the watchdog device name, typically /dev/watchdog. Default is to disable
keep alive support. This should be tested by running the daemon from the
command line before configuring it to start automatically on booting.
- watchdog-timeout = <timeout>
-
Set the watchdog device timeout during startup. If not set, a default is used
that should be set to the kernel timer margin at compile time.
- temperature-sensor = <temp-virtual-file>
-
Set the temperature sensor name. This is normally a 'virtual file' under /sys
and it contains the temperature in milli-Celsius. Usually these are generated
by the
sensors
package, but take care as device enumeration may not be fixed. Default is to
disable temperature checking. Multiple sensors can be used by having repeated
temperature-sensor entries.
- max-temperature = <temp>
-
Set the maximal allowed temperature. Once this temperature is reached the
system is stopped. Default value is 90 C. Watchdog will issue warnings
once the temperature increases 90%, 95% and 98% of this temperature.
- temp-power-off = <yes|no>
-
Set the watchdog action on overheating. Yes option (default) is to power the
machine off, no option is to halt machine and allow Ctrl-Alt-Del reboot.
- file = <filename>
-
Set file name for file mode.
This option can be given as often as you like to check several files.
- change = <mtime>
-
Set the change interval time for file mode. This options
always belongs to the active filename, that is when finding a 'change ='
line watchdog assumes it belongs to the most recently read 'file =' line.
They don't necessarily have to follow each other directly. But you cannot
specify a 'change =' before a 'file ='.
The default is to only stat the file and don't look for changes.
Using this feature to monitor changes in /var/log/messages might require some
special syslog daemon configuration, e.g. rsyslog needs
"$ActionWriteAllMarkMessages on" to be set to make sure the marks are written
no matter what.
- pidfile = <pidfilename>
-
Set pidfile name for server test mode.
This option can be given as often as you like to check several servers.
- ping = <ip-addr>
-
Set IPv4 address for ping mode.
This option can be used more than once to check different
connections.
- interface = <if-name>
-
Set interface name for network mode.
This option can be used more than once to check different
interfaces. Note it is only possible to check physical interfaces, and not
aliased IP interfaces.
- test-binary = <testbin>
-
Execute the given binary to do some user defined tests.
- test-timeout = <timeout in seconds>
-
User defined tests may only run for <timeout> seconds. Set to 0 for unlimited.
- repair-binary = <repbin>
-
Execute the given binary in case of a problem instead of shutting down the
system.
- repair-timeout = <timeout in seconds>
-
repair command may only run for <timeout> seconds. Set to 0 for 'unlimited', but
note that the hardware timer is not refreshed in this case so the system will
hard-reset at some point.
- retry-timeout = <timeout in seconds>
-
Allow most error conditions to persist for <timeout> seconds. Set to 0 for
immediate action (like softboot behaviour).
- repair-maximum = <count>
-
This allows no more then <count> repair attempts against a given fault that
report success (i.e. return 0), but fail to clear the fault, before a reboot
is initiated anyway. If set to zero then a repairable fault can always be
blocked by a repair program reporting success (previous daemon behaviour).
- admin = <mail-address>
-
Email address to send admin mail to. That is, who shall be notified that the
machine is being halted or rebooted. Default is 'root'. If you want to disable
notification via email just set admin to en empty string.
- realtime = <yes|no>
-
If set to yes watchdog will lock itself into memory so it is never swapped
out.
- priority = <schedule priority>
-
Set the schedule priority for realtime mode.
- test-directory = <test directory>
-
Set the directory to run user test/repair scripts. Default is '/etc/watchdog.d'
See the Test Directory section in watchdog(8) for more information.
- log-dir = <log directory>
-
Set the log directory to capture the standard output and standard error from
repair-binary and test-binary execution. Default is '/var/log/watchdog'.
- sigterm-delay = <time in seconds>
-
Set the time on shut down between first sending SIGTERM to all processes, and then
sending SIGKILL. Default is 5 seconds which is generally enough, but systems with
large databases or virtual machines might need longer.
- verbose = <yes|no>
-
This overrides the command line --verbose option. Generally the verbose mode is
only enabled for debugging as it creates a lot of syslog chatter, so use this option
with consideration.
FILES
- /etc/watchdog.conf
-
The watchdog configuration file
- /etc/watchdog.d
-
A directory containing test-or-repair commands. See the Test Directory
section in watchdog(8) for more information.