SYNOPSIS
xl subcommand [args]DESCRIPTION
The xl program is the new tool for managing Xen guest domains. The program can be used to create, pause, and shutdown domains. It can also be used to list current domains, enable or pin VCPUs, and attach or detach virtual block devices. The old xm tool is deprecated and should not be used.The basic structure of every xl command is almost always:
- xl subcommand [OPTIONS] domain-id
Where subcommand is one of the subcommands listed below, domain-id is the numeric domain id, or the domain name (which will be internally translated to domain id), and OPTIONS are subcommand specific options. There are a few exceptions to this rule in the cases where the subcommand in question acts on all domains, the entire machine, or directly on the Xen hypervisor. Those exceptions will be clear for each of those subcommands.
NOTES
- start the script /etc/init.d/xencommons at boot time
- Most xl operations rely upon xenstored and xenconsoled: make sure you start the script /etc/init.d/xencommons at boot time to initialize all the daemons needed by xl.
- setup a xenbr0 bridge in dom0
- In the most common network configuration, you need to setup a bridge in dom0 named xenbr0 in order to have a working network in the guest domains. Please refer to the documentation of your Linux distribution to know how to setup the bridge.
- autoballoon
- If you specify the amount of memory dom0 has, passing dom0_mem to Xen, it is highly recommended to disable autoballoon. Edit /etc/xen/xl.conf and set it to 0.
- run xl as root
- Most xl commands require root privileges to run due to the communications channels used to talk to the hypervisor. Running as non root will return an error.
GLOBAL OPTIONS
Some global options are always available:- -v
- Verbose.
- -N
- Dry run: do not actually execute the command.
- -f
- Force execution: xl will refuse to run some commands if it detects that xend is also running, this option will force the execution of those commands, even though it is unsafe.
DOMAIN SUBCOMMANDS
The following subcommands manipulate domains directly. As stated previously, most commands take domain-id as the first parameter.- button-press domain-id button
-
This command is deprecated. Please use "xl trigger" in preference
Indicate an ACPI button press to the domain. button is may be 'power' or 'sleep'. This command is only available for HVM domains.
- create [configfile] [OPTIONS]
-
The create subcommand takes a config file as first argument: see
xl.cfg for full details of that file format and possible options.
If configfile is missing XL creates the domain starting from the
default value for every option.
configfile has to be an absolute path to a file.
Create will return as soon as the domain is started. This does not mean the guest OS in the domain has actually booted, or is available for input.
OPTIONS
-
- -q, --quiet
- No console output.
- -f=FILE, --defconfig=FILE
- Use the given configuration file.
- -p
- Leave the domain paused after it is created.
- -V, --vncviewer
- Attach to domain's VNC server, forking a vncviewer process.
- -A, --vncviewer-autopass
- Pass VNC password to vncviewer via stdin.
- -c
- Attach console to the domain as soon as it has started. This is useful for determining issues with crashing domains and just as a general convenience since you often want to watch the domain boot.
- key=value
- It is possible to pass key=value pairs on the command line to provide options as if they were written in the configuration file; these override whatever is in the configfile.
-
EXAMPLES
- with config file
-
xl create DebianLenny
This creates a domain with the file /etc/xen/DebianLenny, and returns as soon as it is run.
-
- config-update domid [configfile] [OPTIONS]
-
Update the saved configuration for a running domain. This has no
immediate effect but will be applied when the guest is next
restarted. This command is useful to ensure that runtime modifications
made to the guest will be preserved when the guest is restarted.
configfile has to be an absolute path to a file.
OPTIONS
-
- -f=FILE, --defconfig=FILE
- Use the given configuration file.
- key=value
- It is possible to pass key=value pairs on the command line to provide options as if they were written in the configuration file; these override whatever is in the configfile.
-
- console [OPTIONS] domain-id
-
Attach to domain domain-id's console. If you've set up your domains to
have a traditional log in console this will look much like a normal
text log in screen.
Use the key combination Ctrl+] to detach the domain console.
OPTIONS
-
- -t [pv|serial]
- Connect to a PV console or connect to an emulated serial console. PV consoles are the only consoles available for PV domains while HVM domains can have both. If this option is not specified it defaults to emulated serial for HVM guests and PV console for PV guests.
- -n NUM
- Connect to console number NUM. Console numbers start from 0.
-
- destroy domain-id
- Immediately terminate the domain domain-id. This doesn't give the domain OS any chance to react, and is the equivalent of ripping the power cord out on a physical machine. In most cases you will want to use the shutdown command instead.
- domid domain-name
- Converts a domain name to a domain id.
- domname domain-id
- Converts a domain id to a domain name.
- rename domain-id new-name
- Change the domain name of domain-id to new-name.
- dump-core domain-id [filename]
- Dumps the virtual machine's memory for the specified domain to the filename specified, without pausing the domain. The dump file will be written to a distribution specific directory for dump files. Such as: /var/lib/xen/dump or /var/xen/dump.
- help [--long]
-
Displays the short help message (i.e. common commands).
The --long option prints out the complete set of xl subcommands, grouped by function.
- list [OPTIONS] [domain-id ...]
-
Prints information about one or more domains. If no domains are
specified it prints out information about all domains.
OPTIONS
-
- -l, --long
- The output for xl list is not the table view shown below, but instead presents the data in as a JSON data structure.
- -Z, --context Also prints the security labels.
- -v, --verbose
- Also prints the domain UUIDs, the shutdown reason and security labels.
-
EXAMPLE
An example format for the list is as follows:
Name ID Mem VCPUs State Time(s) Domain-0 0 750 4 r----- 11794.3 win 1 1019 1 r----- 0.3 linux 2 2048 2 r----- 5624.2
Name is the name of the domain. ID the numeric domain id. Mem is the desired amount of memory to allocate to the domain (although it may not be the currently allocated amount). VCPUs is the number of virtual CPUs allocated to the domain. State is the run state (see below). Time is the total run time of the domain as accounted for by Xen.
STATES
The State field lists 6 states for a Xen domain, and which ones the current domain is in.
- r - running
- The domain is currently running on a CPU.
- b - blocked
- The domain is blocked, and not running or runnable. This can be caused because the domain is waiting on IO (a traditional wait state) or has gone to sleep because there was nothing else for it to do.
- p - paused
- The domain has been paused, usually occurring through the administrator running xl pause. When in a paused state the domain will still consume allocated resources like memory, but will not be eligible for scheduling by the Xen hypervisor.
- s - shutdown
- The guest OS has shut down (SCHEDOP_shutdown has been called) but the domain is not dying yet.
- c - crashed
- The domain has crashed, which is always a violent ending. Usually this state can only occur if the domain has been configured not to restart on crash. See xl.cfg(5) for more info.
- d - dying
- The domain is in process of dying, but hasn't completely shutdown or crashed.
-
NOTES
- The Time column is deceptive. Virtual IO (network and block devices) used by domains requires coordination by Domain0, which means that Domain0 is actually charged for much of the time that a DomainU is doing IO. Use of this time value to determine relative utilizations by domains is thus very suspect, as a high IO workload may show as less utilized than a high CPU workload. Consider yourself warned.
-
- mem-max domain-id mem
-
Specify the maximum amount of memory the domain is able to use, appending 't'
for terabytes, 'g' for gigabytes, 'm' for megabytes, 'k' for kilobytes and 'b'
for bytes.
The mem-max value may not correspond to the actual memory used in the domain, as it may balloon down its memory to give more back to the OS.
- mem-set domain-id mem
-
Set the domain's used memory using the balloon driver; append 't' for
terabytes, 'g' for gigabytes, 'm' for megabytes, 'k' for kilobytes and 'b' for
bytes.
Because this operation requires cooperation from the domain operating system, there is no guarantee that it will succeed. This command will definitely not work unless the domain has the required paravirt driver.
Warning: There is no good way to know in advance how small of a mem-set will make a domain unstable and cause it to crash. Be very careful when using this command on running domains.
- migrate [OPTIONS] domain-id host
-
Migrate a domain to another host machine. By default xl relies on ssh as a
transport mechanism between the two hosts.
OPTIONS
-
- -s sshcommand
- Use <sshcommand> instead of ssh. String will be passed to sh. If empty, run <host> instead of ssh <host> xl migrate-receive [-d -e].
- -e
- On the new host, do not wait in the background (on <host>) for the death of the domain. See the corresponding option of the create subcommand.
- -C config
- Send <config> instead of config file from creation.
- --debug
- Print huge (!) amount of debug during the migration process.
-
- remus [OPTIONS] domain-id host
-
Enable Remus HA for domain. By default xl relies on ssh as a transport
mechanism between the two hosts.
N.B: Remus support in xl is still in experimental (proof-of-concept) phase.
There is no support for network or disk buffering at the moment.OPTIONS
-
- -i MS
- Checkpoint domain memory every MS milliseconds (default 200ms).
- -b
- Replicate memory checkpoints to /dev/null (blackhole). Generally useful for debugging.
- -u
- Disable memory checkpoint compression.
- -s sshcommand
- Use <sshcommand> instead of ssh. String will be passed to sh. If empty, run <host> instead of ssh <host> xl migrate-receive -r [-e].
- -e
- On the new host, do not wait in the background (on <host>) for the death of the domain. See the corresponding option of the create subcommand.
-
- pause domain-id
- Pause a domain. When in a paused state the domain will still consume allocated resources such as memory, but will not be eligible for scheduling by the Xen hypervisor.
- reboot [OPTIONS] domain-id
-
Reboot a domain. This acts just as if the domain had the reboot
command run from the console. The command returns as soon as it has
executed the reboot action, which may be significantly before the
domain actually reboots.
For HVM domains this requires PV drivers to be installed in your guest OS. If PV drivers are not present but you have configured the guest OS to behave appropriately you may be able to use the -F option trigger a reset button press.
The behavior of what happens to a domain when it reboots is set by the on_reboot parameter of the domain configuration file when the domain was created.
OPTIONS
-
- -F
-
If the guest does not support PV reboot control then fallback to
sending an ACPI power event (equivalent to the reset option to
trigger.
You should ensure that the guest is configured to behave as expected in response to this event.
-
- restore [OPTIONS] [ConfigFile] CheckpointFile
-
Build a domain from an xl save state file. See save for more info.
OPTIONS
-
- -p
- Do not unpause domain after restoring it.
- -e
- Do not wait in the background for the death of the domain on the new host. See the corresponding option of the create subcommand.
- -d
- Enable debug messages.
- -V, --vncviewer
- Attach to domain's VNC server, forking a vncviewer process.
- -A, --vncviewer-autopass
- Pass VNC password to vncviewer via stdin.
-
- save [OPTIONS] domain-id CheckpointFile [ConfigFile]
-
Saves a running domain to a state file so that it can be restored
later. Once saved, the domain will no longer be running on the
system, unless the -c or -p options are used.
xl restore restores from this checkpoint file.
Passing a config file argument allows the user to manually select the VM config
file used to create the domain.
-
- -c
- Leave domain running after creating the snapshot.
- -p
- Leave domain paused after creating the snapshot.
-
- sharing [domain-id]
-
List count of shared pages.
OPTIONS
-
- domain_id
- List specifically for that domain. Otherwise, list for all domains.
-
- shutdown [OPTIONS] -a|domain-id
-
Gracefully shuts down a domain. This coordinates with the domain OS
to perform graceful shutdown, so there is no guarantee that it will
succeed, and may take a variable length of time depending on what
services must be shutdown in the domain.
For HVM domains this requires PV drivers to be installed in your guest OS. If PV drivers are not present but you have configured the guest OS to behave appropriately you may be able to use the -F option trigger a power button press.
The command returns immediately after signally the domain unless that -w flag is used.
The behavior of what happens to a domain when it reboots is set by the on_shutdown parameter of the domain configuration file when the domain was created.
OPTIONS
-
- -a, --all
- Shutdown all guest domains. Often used when doing a complete shutdown of a Xen system.
- -w, --wait
- Wait for the domain to complete shutdown before returning.
- -F
-
If the guest does not support PV shutdown control then fallback to
sending an ACPI power event (equivalent to the power option to
trigger.
You should ensure that the guest is configured to behave as expected in response to this event.
-
- sysrq domain-id letter
- Send a <Magic System Request> to the domain, each type of request is represented by a different letter. It can be used to send SysRq requests to Linux guests, see sysrq.txt in your Linux Kernel sources for more information. It requires PV drivers to be installed in your guest OS.
- trigger domain-id nmi|reset|init|power|sleep|s3resume [VCPU]
- Send a trigger to a domain, where the trigger can be: nmi, reset, init, power or sleep. Optionally a specific vcpu number can be passed as an argument. This command is only available for HVM domains.
- unpause domain-id
- Moves a domain out of the paused state. This will allow a previously paused domain to now be eligible for scheduling by the Xen hypervisor.
- vcpu-set domain-id vcpu-count
-
Enables the vcpu-count virtual CPUs for the domain in question.
Like mem-set, this command can only allocate up to the maximum virtual
CPU count configured at boot for the domain.
If the vcpu-count is smaller than the current number of active VCPUs, the highest number VCPUs will be hotplug removed. This may be important for pinning purposes.
Attempting to set the VCPUs to a number larger than the initially configured VCPU count is an error. Trying to set VCPUs to < 1 will be quietly ignored.
Some guests may need to actually bring the newly added CPU online after vcpu-set, go to SEE ALSO section for information.
- vcpu-list [domain-id]
- Lists VCPU information for a specific domain. If no domain is specified, VCPU information for all domains will be provided.
- vcpu-pin domain-id vcpu cpus
-
Pins the VCPU to only run on the specific CPUs. The keyword
all can be used to apply the cpus list to all VCPUs in the
domain.
Normally VCPUs can float between available CPUs whenever Xen deems a different run state is appropriate. Pinning can be used to restrict this, by ensuring certain VCPUs can only run on certain physical CPUs.
- vm-list
-
Prints information about guests. This list excludes information about
service or auxiliary domains such as dom0 and stubdoms.
EXAMPLE
An example format for the list is as follows:
UUID ID name 59e1cf6c-6ab9-4879-90e7-adc8d1c63bf5 2 win 50bc8f75-81d0-4d53-b2e6-95cb44e2682e 3 linux
- vncviewer [OPTIONS] domain-id
-
Attach to domain's VNC server, forking a vncviewer process.
OPTIONS
-
- --autopass
- Pass VNC password to vncviewer via stdin.
-
XEN HOST SUBCOMMANDS
- debug-keys keys
- Send debug keys to Xen. It is the same as pressing the Xen ``conswitch'' (Ctrl-A by default) three times and then pressing ``keys''.
- dmesg [-c]
-
Reads the Xen message buffer, similar to dmesg on a Linux system. The
buffer contains informational, warning, and error messages created
during Xen's boot process. If you are having problems with Xen, this
is one of the first places to look as part of problem determination.
OPTIONS
-
- -c, --clear
- Clears Xen's message buffer.
-
- info [-n, --numa]
-
Print information about the Xen host in name : value format. When
reporting a Xen bug, please provide this information as part of the
bug report. See http://wiki.xen.org/xenwiki/ReportingBugs on how to
report Xen bugs.
Sample output looks as follows:
host : scarlett release : 3.1.0-rc4+ version : #1001 SMP Wed Oct 19 11:09:54 UTC 2011 machine : x86_64 nr_cpus : 4 nr_nodes : 1 cores_per_socket : 4 threads_per_core : 1 cpu_mhz : 2266 hw_caps : bfebfbff:28100800:00000000:00003b40:009ce3bd:00000000:00000001:00000000 virt_caps : hvm hvm_directio total_memory : 6141 free_memory : 4274 free_cpus : 0 outstanding_claims : 0 xen_major : 4 xen_minor : 2 xen_extra : -unstable xen_caps : xen-3.0-x86_64 xen-3.0-x86_32p hvm-3.0-x86_32 hvm-3.0-x86_32p hvm-3.0-x86_64 xen_scheduler : credit xen_pagesize : 4096 platform_params : virt_start=0xffff800000000000 xen_changeset : Wed Nov 02 17:09:09 2011 +0000 24066:54a5e994a241 xen_commandline : com1=115200,8n1 guest_loglvl=all dom0_mem=750M console=com1 cc_compiler : gcc version 4.4.5 (Debian 4.4.5-8) cc_compile_by : sstabellini cc_compile_domain : uk.xensource.com cc_compile_date : Tue Nov 8 12:03:05 UTC 2011 xend_config_format : 4
FIELDS
Not all fields will be explained here, but some of the less obvious ones deserve explanation:
-
- hw_caps
- A vector showing what hardware capabilities are supported by your processor. This is equivalent to, though more cryptic, the flags field in /proc/cpuinfo on a normal Linux machine: they both derive from the feature bits returned by the cpuid command on x86 platforms.
- free_memory
- Available memory (in MB) not allocated to Xen, or any other domains, or claimed for domains.
- outstanding_claims
- When a claim call is done (see xl.conf) a reservation for a specific amount of pages is set and also a global value is incremented. This global value (outstanding_claims) is then reduced as the domain's memory is populated and eventually reaches zero. Most of the time the value will be zero, but if you are launching multiple guests, and claim_mode is enabled, this value can increase/decrease. Note that the value also affects the free_memory - as it will reflect the free memory in the hypervisor minus the outstanding pages claimed for guests. See xl info claims parameter for detailed listing.
- xen_caps
- The Xen version and architecture. Architecture values can be one of: x86_32, x86_32p (i.e. PAE enabled), x86_64, ia64.
- xen_changeset
- The Xen mercurial changeset id. Very useful for determining exactly what version of code your Xen system was built from.
-
OPTIONS
- -n, --numa
- List host NUMA topology information
-
- top
- Executes the xentop command, which provides real time monitoring of domains. Xentop is a curses interface, and reasonably self explanatory.
- uptime
- Prints the current uptime of the domains running.
- claims
-
Prints information about outstanding claims by the guests. This provides
the outstanding claims and currently populated memory count for the guests.
These values added up reflect the global outstanding claim value, which
is provided via the info argument, outstanding_claims value.
The Mem column has the cumulative value of outstanding claims and
the total amount of memory that has been right now allocated to the guest.
EXAMPLE
An example format for the list is as follows:
Name ID Mem VCPUs State Time(s) Claimed Domain-0 0 2047 4 r----- 19.7 0 OL5 2 2048 1 --p--- 0.0 847 OL6 3 1024 4 r----- 5.9 0 Windows_XP 4 2047 1 --p--- 0.0 1989
In which it can be seen that the OL5 guest still has 847MB of claimed memory (out of the total 2048MB where 1191MB has been allocated to the guest).
SCHEDULER SUBCOMMANDS
Xen ships with a number of domain schedulers, which can be set at boot time with the sched= parameter on the Xen command line. By default credit is used for scheduling.- sched-credit [OPTIONS]
-
Set or get credit scheduler parameters. The credit scheduler is a
proportional fair share CPU scheduler built from the ground up to be
work conserving on SMP hosts.
Each domain (including Domain0) is assigned a weight and a cap.
OPTIONS
-
- -d DOMAIN, --domain=DOMAIN
- Specify domain for which scheduler parameters are to be modified or retrieved. Mandatory for modifying scheduler parameters.
- -w WEIGHT, --weight=WEIGHT
- A domain with a weight of 512 will get twice as much CPU as a domain with a weight of 256 on a contended host. Legal weights range from 1 to 65535 and the default is 256.
- -c CAP, --cap=CAP
-
The cap optionally fixes the maximum amount of CPU a domain will be
able to consume, even if the host system has idle CPU cycles. The cap
is expressed in percentage of one physical CPU: 100 is 1 physical CPU,
50 is half a CPU, 400 is 4 CPUs, etc. The default, 0, means there is
no upper cap.
NB: Many systems have features that will scale down the computing power of a cpu that is not 100% utilized. This can be in the operating system, but can also sometimes be below the operating system in the BIOS. If you set a cap such that individual cores are running at less than 100%, this may have an impact on the performance of your workload over and above the impact of the cap. For example, if your processor runs at 2GHz, and you cap a vm at 50%, the power management system may also reduce the clock speed to 1GHz; the effect will be that your VM gets 25% of the available power (50% of 1GHz) rather than 50% (50% of 2GHz). If you are not getting the performance you expect, look at performance and cpufreq options in your operating system and your BIOS.
- -p CPUPOOL, --cpupool=CPUPOOL
- Restrict output to domains in the specified cpupool.
- -s, --schedparam
- Specify to list or set pool-wide scheduler parameters.
- -t TSLICE, --tslice_ms=TSLICE
- Timeslice tells the scheduler how long to allow VMs to run before pre-empting. The default is 30ms. Valid ranges are 1ms to 1000ms. The length of the timeslice (in ms) must be higher than the length of the ratelimit (see below).
- -r RLIMIT, --ratelimit_us=RLIMIT
- Ratelimit attempts to limit the number of schedules per second. It sets a minimum amount of time (in microseconds) a VM must run before we will allow a higher-priority VM to pre-empt it. The default value is 1000 microseconds (1ms). Valid range is 100 to 500000 (500ms). The ratelimit length must be lower than the timeslice length.
-
COMBINATION
The following is the effect of combining the above options:
- <nothing> : List all domain params and sched params from all pools
- -d [domid] : List domain params for domain [domid]
- -d [domid] [params] : Set domain params for domain [domid]
- -p [pool] : list all domains and sched params for [pool]
- -s : List sched params for poolid 0
- -s [params] : Set sched params for poolid 0
- -p [pool] -s : List sched params for [pool]
- -p [pool] -s [params] : Set sched params for [pool]
- -p [pool] -d... : Illegal
-
- sched-credit2 [OPTIONS]
-
Set or get credit2 scheduler parameters. The credit2 scheduler is a
proportional fair share CPU scheduler built from the ground up to be
work conserving on SMP hosts.
Each domain (including Domain0) is assigned a weight.
OPTIONS
-
- -d DOMAIN, --domain=DOMAIN
- Specify domain for which scheduler parameters are to be modified or retrieved. Mandatory for modifying scheduler parameters.
- -w WEIGHT, --weight=WEIGHT
- A domain with a weight of 512 will get twice as much CPU as a domain with a weight of 256 on a contended host. Legal weights range from 1 to 65535 and the default is 256.
- -p CPUPOOL, --cpupool=CPUPOOL
- Restrict output to domains in the specified cpupool.
-
- sched-sedf [OPTIONS]
-
Set or get Simple EDF (Earliest Deadline First) scheduler parameters. This
scheduler provides weighted CPU sharing in an intuitive way and uses
realtime-algorithms to ensure time guarantees. For more information see
docs/misc/sedf_scheduler_mini-HOWTO.txt in the Xen distribution.
OPTIONS
-
- -d DOMAIN, --domain=DOMAIN
- Specify domain for which scheduler parameters are to be modified or retrieved. Mandatory for modifying scheduler parameters.
- -p PERIOD, --period=PERIOD
- The normal EDF scheduling usage in milliseconds.
- -s SLICE, --slice=SLICE
- The normal EDF scheduling usage in milliseconds.
- -l LATENCY, --latency=LATENCY
- Scaled period if domain is doing heavy I/O.
- -e EXTRA, --extra=EXTRA
- Flag for allowing domain to run in extra time (0 or 1).
- -w WEIGHT, --weight=WEIGHT
- Another way of setting CPU slice.
- -c CPUPOOL, --cpupool=CPUPOOL
- Restrict output to domains in the specified cpupool.
-
CPUPOOLS COMMANDS
Xen can group the physical cpus of a server in cpu-pools. Each physical CPU is assigned at most to one cpu-pool. Domains are each restricted to a single cpu-pool. Scheduling does not cross cpu-pool boundaries, so each cpu-pool has an own scheduler. Physical cpus and domains can be moved from one cpu-pool to another only by an explicit command. Cpu-pools can be specified either by name or by id.- cpupool-create [OPTIONS] [ConfigFile] [Variable=Value ...]
-
Create a cpu pool based an config from a ConfigFile or command-line
parameters. Variable settings from the ConfigFile may be altered
by specifying new or additional assignments on the command line.
See the xlcpupool.cfg(5) manpage for more information.
OPTIONS
-
- -f=FILE, --defconfig=FILE
- Use the given configuration file.
-
- cpupool-list [-c|--cpus] [cpu-pool]
- List CPU pools on the host. If -c is specified, xl prints a list of CPUs used by cpu-pool.
- cpupool-destroy cpu-pool
- Deactivates a cpu pool. This is possible only if no domain is active in the cpu-pool.
- cpupool-rename cpu-pool <newname>
- Renames a cpu-pool to newname.
- cpupool-cpu-add cpu-pool cpu-nr|node:node-nr
- Adds a cpu or all cpus of a numa node to a cpu-pool.
- cpupool-cpu-remove cpu-nr|node:node-nr
- Removes a cpu or all cpus of a numa node from a cpu-pool.
- cpupool-migrate domain cpu-pool
- Moves a domain specified by domain-id or domain-name into a cpu-pool.
- cpupool-numa-split
- Splits up the machine into one cpu-pool per numa node.
VIRTUAL DEVICE COMMANDS
Most virtual devices can be added and removed while guests are running, assuming that the necessary support exists in the guest. The effect to the guest OS is much the same as any hotplug event.BLOCK DEVICES
- block-attach domain-id disc-spec-component(s) ...
-
Create a new virtual block device. This will trigger a hotplug event
for the guest.
OPTIONS
-
- domain-id
- The domain id of the guest domain that the device will be attached to.
- disc-spec-component
- A disc specification in the same format used for the disk variable in the domain config file. See <http://xenbits.xen.org/docs/unstable/misc/xl-disk-configuration.txt>.
-
- block-detach domain-id devid [--force]
-
Detach a domain's virtual block device. devid may be the symbolic
name or the numeric device id given to the device by domain 0. You
will need to run xl block-list to determine that number.
Detaching the device requires the cooperation of the domain. If the domain fails to release the device (perhaps because the domain is hung or is still using the device), the detach will fail. The --force parameter will forcefully detach the device, but may cause IO errors in the domain.
- block-list domain-id
- List virtual block devices for a domain.
- cd-insert domain-id VirtualDevice target
-
Insert a cdrom into a guest domain's existing virtial cd drive. The
virtual drive must already exist but can be current empty.
Only works with HVM domains.
OPTIONS
-
- VirtualDevice
- How the device should be presented to the guest domain; for example ``hdc''.
- target
- the target path in the backend domain (usually domain 0) to be exported; Can be a block device or a file etc. See target in docs/misc/xl-disk-configuration.txt.
-
- cd-eject domain-id VirtualDevice
-
Eject a cdrom from a guest's virtual cd drive. Only works with HVM domains.
OPTIONS
-
- VirtualDevice
- How the device should be presented to the guest domain; for example ``hdc''.
-
NETWORK DEVICES
- network-attach domain-id network-device
- Creates a new network device in the domain specified by domain-id. network-device describes the device to attach, using the same format as the vif string in the domain config file. See xl.cfg and <http://xenbits.xen.org/docs/unstable/misc/xl-network-configuration.html> for more informations.
- network-detach domain-id devid|mac
- Removes the network device from the domain specified by domain-id. devid is the virtual interface device number within the domain (i.e. the 3 in vif22.3). Alternatively the mac address can be used to select the virtual interface to detach.
- network-list domain-id
- List virtual network interfaces for a domain.
VTPM DEVICES
- vtpm-attach domain-id vtpm-device
- Creates a new vtpm device in the domain specified by domain-id. vtpm-device describes the device to attach, using the same format as the vtpm string in the domain config file. See xl.cfg for more information.
- vtpm-detach domain-id devid|uuid
- Removes the vtpm device from the domain specified by domain-id. devid is the numeric device id given to the virtual trusted platform module device. You will need to run xl vtpm-list to determine that number. Alternatively the uuid of the vtpm can be used to select the virtual device to detach.
- vtpm-list domain-id
- List virtual trusted platform modules for a domain.
PCI PASS-THROUGH
- pci-assignable-list
- List all the assignable PCI devices. These are devices in the system which are configured to be available for passthrough and are bound to a suitable PCI backend driver in domain 0 rather than a real driver.
- pci-assignable-add BDF
-
Make the device at PCI Bus/Device/Function BDF assignable to guests.
This will bind the device to the pciback driver. If it is already
bound to a driver, it will first be unbound, and the original driver
stored so that it can be re-bound to the same driver later if desired.
If the device is already bound, it will return success.
CAUTION: This will make the device unusable by Domain 0 until it is returned with pci-assignable-remove. Care should therefore be taken not to do this on a device critical to domain 0's operation, such as storage controllers, network interfaces, or GPUs that are currently being used.
- pci-assignable-remove [-r] BDF
- Make the device at PCI Bus/Device/Function BDF assignable to guests. This will at least unbind the device from pciback. If the -r option is specified, it will also attempt to re-bind the device to its original driver, making it usable by Domain 0 again. If the device is not bound to pciback, it will return success.
- pci-attach domain-id BDF
- Hot-plug a new pass-through pci device to the specified domain. BDF is the PCI Bus/Device/Function of the physical device to pass-through.
- pci-detach [-f] domain-id BDF
-
Hot-unplug a previously assigned pci device from a domain. BDF is the PCI
Bus/Device/Function of the physical device to be removed from the guest domain.
If -f is specified, xl is going to forcefully remove the device even without guest's collaboration.
- pci-list domain-id
- List pass-through pci devices for a domain.
TMEM
- tmem-list I[<-l>] domain-id
- List tmem pools. If -l is specified, also list tmem stats.
- tmem-freeze domain-id
- Freeze tmem pools.
- tmem-thaw domain-id
- Thaw tmem pools.
- tmem-set domain-id [OPTIONS]
-
Change tmem settings.
OPTIONS
-
- -w WEIGHT
- Weight (int)
- -c CAP
- Cap (int)
- -p COMPRESS
- Compress (int)
-
- tmem-shared-auth domain-id [OPTIONS]
-
De/authenticate shared tmem pool.
OPTIONS
-
- -u UUID
- Specify uuid (abcdef01-2345-6789-1234-567890abcdef)
- -a AUTH
- 0=auth,1=deauth
-
- tmem-freeable
- Get information about how much freeable memory (MB) is in-use by tmem.
FLASK
FLASK is a security framework that defines a mandatory access control policy providing fine-grained controls over Xen domains, allowing the policy writer to define what interactions between domains, devices, and the hypervisor are permitted. Some example of what you can do using XSM/FLASK:- Prevent two domains from communicating via event channels or grants
- Control which domains can use device passthrough (and which devices)
- Restrict or audit operations performed by privileged domains
- Prevent a privileged domain from arbitrarily mapping pages from other
domains.
You can find more details on how to use FLASK and an example security policy here: <http://xenbits.xen.org/docs/unstable/misc/xsm-flask.txt>
- getenforce
- Determine if the FLASK security module is loaded and enforcing its policy.
- setenforce 1|0|Enforcing|Permissive
- Enable or disable enforcing of the FLASK access controls. The default is permissive and can be changed using the flask_enforcing option on the hypervisor's command line.
- loadpolicy policy-file
- Load FLASK policy from the given policy file. The initial policy is provided to the hypervisor as a multiboot module; this command allows runtime updates to the policy. Loading new security policy will reset runtime changes to device labels.
TO BE DOCUMENTED
We need better documentation for:- tmem
- Transcendent Memory.
BUGS
Send bugs to [email protected], see http://wiki.xen.org/xenwiki/ReportingBugs on how to send bug reports.