ola_trigger(1)
Run programs based on the values in a DMX stream.
SYNOPSIS
ola_trigger
[ options ] <config_file>
DESCRIPTION
ola_trigger
Run programs based on the values in a DMX stream.
OPTIONS
- -h, --help
-
Display the help message
- -l, --log-level <int8_t>
-
Set the logging level 0 .. 4.
- -o, --offset <uint16_t>
-
Apply an offset to the slot numbers. Valid offsets are 0 to 512, default is 0.
- -u, --universe <uint32_t>
-
The universe to use, defaults to 0.
- --validate
-
Validate the config file, rather than running it.
- -v, --version
-
Display version information
- --syslog
-
Send to syslog rather than stderr.
- --no-use-epoll
-
Disable the use of epoll(), revert to select()
- --no-use-kqueue
-
Disable the use of kqueue(), revert to select()
- --scheduler-policy <policy>
-
The thread scheduling policy, one of {fifo, rr}.
- --scheduler-priority <priority>
-
The thread priority, only used if --scheduler-policy is set.