SYNOPSIS
esorex muse_scipost_calibrate_flux [OPTIONS] FILE.sof
DESCRIPTION
Replace the intensity in the MUSE pixel tables by the absolute flux. This is a task separated from muse_scipost.
OPTIONS
- --lambdamin <float>
- Cut off the data below this wavelength after loading the pixel table(s). (float; default: 4000.0). The full name of this option for the EsoRex configuration file is muse.muse_scipost_calibrate_flux.lambdamin [default = 4000.0].
- --lambdamax <float>
-
Cut off the data above this wavelength after loading the pixel
table(s). (float; default: 10000.0). The full name of this option for the EsoRex configuration
file is muse.muse_scipost_calibrate_flux.lambdamax [default = 10000.0].
Note that it is possible to create a configuration file containing these options, along with suitable default values. Please refer to the details provided by the 'esorex --help' command.
VERSION
muse_scipost_calibrate_flux 1.6.2
BUG REPORTS
Please report any problems to [email protected]. Alternatively, you may send a report to the ESO User Support Department <[email protected]>.
LICENSE
This file is part of the MUSE Instrument Pipeline Copyright (C) 2005, 2015 European Southern ObservatoryThis program is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with this program; if not, write to the Free Software Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02111-1307 USA