SYNOPSYS
-
ploop init
-s
size
[-f format]
[-v version]
[-t fstype]
[-b blocksize]
[-B fsblocksize]
[--nolazy ]
delta_file
- ploop mount
[-r ] [-F ] [-f format] [-b blocksize] [-d device] [-m mount_point] [-o mount_options] [-t fstype] base_delta [... top_delta]- ploop mount
[-r ] [-F ] [-d device] [-m mount_point] [-o mount_options] [-t fstype] [-u uuid] DiskDescriptor.xml- ploop umount
{ -d device | -m mount_point | DiskDescriptor.xml | image_file }- ploop replace
{ -u uuid | -l level | -o cur_image_file } [--keep-name ] -i image_file DiskDescriptor.xml- ploop resize
-s size DiskDescriptor.xml- ploop convert
{ -f format | -v version } DiskDescriptor.xml- ploop check
[-u uuid] DiskDescriptor.xml- ploop check
[--force ] [--hard-force ] [--check ] [--ro ] [--silent ] [--drop-inuse ] [--raw ] [--blocksize size] [--repair-sparse ] image_file- ploop info
[-s ] [-d ] DiskDescriptor.xml- ploop list
[-a ]- ploop snapshot
[-u uuid] DiskDescriptor.xml- ploop snapshot-merge
[-u uuid [-U uuid2] | -A] [-n new_delta] DiskDescriptor.xml- ploop snapshot-switch
-u uuid DiskDescriptor.xml- ploop snapshot-delete
-u uuid DiskDescriptor.xml- ploop snapshot-list
[-H ] [-u uuid] [-s ] [-o field[,field...]] DiskDescriptor.xml- ploop copy
-s device [-F stop_command] { [-d file] | [-o output_fd] [-f feedback_fd] }- ploop copy
-d file [-i input_fd] [-f feedback_fd]- ploop balloon discard
[--automount ] [--to-free size] [--min-block min_size] [--defrag ] DiskDescriptor.xml- ploop restore-descriptor
-f format [-b blocksize] disk_dir delta_file
DESCRIPTION
Note that this ploop tool is not aware of container entities. Commands that have DiskDescriptor.xml as an argument work with an XML file that contains meta-information about a particular ploop device configuration: device characteristics (block size etc.), storage information (names and formats of images used for the device), snapshot information, etc. If a particular command can be used both with and without the DiskDescriptor.xml argument, it is strongly advised to use the form with DiskDescriptor.xml.
OPTIONS
Run ploop without any options to show a short synopsys, including a list of commands.
Run ploop command to show synopsys and a short description for a particular command.
Basic commands
Create and initalize a ploop image file and a corresponding DiskDescriptor.xml file.
-
ploop init
-s
size
[-f format]
[-v version]
[-t fstype]
[-b blocksize]
[-B fsblocksize]
[--nolazy ]
delta_file
- -s size
-
- Image size. If no suffix is specified, the size is in sector units (one sector is 512 bytes). One can specify optional K, M, G or T suffix to set the size in kilo-, mega-, giga- or terabytes.
- -f format
- Image format. See Image formats below.
- -v version
- Image version, can be 1 or 2. Default is 2, if supported by the kernel.
- -t none|ext3|ext4
- File system type to create, default is ext4. Unless none is specified, a partition, a filesystem, and a balloon file will be created inside the image. Using ext3 is not recommended.
- -b blocksize
- Device block size, in 512 byte sectors. Default block size is 2048 sectors, or 1 megabyte.
- -B fsblocksize
- Filesystem block size, in bytes. Default is 4096 bytes.
- -n, --nolazy
- Disable lazy mkfs initialization (which is enabled by default). Currently that means if this flag is set, mkfs.ext4(8) is called with -Elazy_itable_init=0,lazy_journal_init=0 options.
- delta_file
-
Path to a non-existent image file to be created.
Assemble a ploop device from one or more delta images, start it, and optionally mount the file system residing on the device.
Two forms of this command are provided. The first one accepts a list of delta images to be used for assembling the ploop device, while the second one is using information from a DiskDescriptor.xml file. Please note that not all mount options are applicable to both forms.
-
ploop mount
[-r ]
[-F ]
[-f format]
[-b blocksize]
[-d device]
[-m mount_point]
[-o mount_options]
[-t fstype]
base_delta
[...
top_delta]
- ploop mount
[-r ] [-F ] [-d device] [-m mount_point] [-o mount_options] [-t fstype] [-u uuid] DiskDescriptor.xml- -r
-
- Mount as read-only.
- -F
- Run fsck(8) on inner filesystem before mounting it. This option is ignored if -m is not used.
- -f format
- Image format. Ignored if DiskDescriptor.xml is specified. Otherwise, one need to specify raw as an argument, if raw image format is used.
- -b blocksize
- Device block size, in 512 byte sectors. Ignored if DiskDescriptor.xml is specified. Otherwise, required for raw images.
- -d device
- Ploop device to use, e.g. /dev/ploop0. If not specified, a randomly numbered ploop device will be used.
- -m mount_point
- If this option is specified, ploop goes on to mount the file system to directory denoted by mount_point.
- -o mount_options
- Any additional mount options, comma-separated. Used if -m is set.
- -t fstype
- File system type used for mounting. Used if -m is set. The default is ext4.
- -u uuid | base
- GUID of the image from the DiskDescriptor.xml to be mounted. By default, top GUID is used. The special 'base' value can be used to mount the base (lower-level) image.
- base_delta [... top_delta]
- List of image files to mount, with the first one being the base delta and the last one being the top delta (i.e. the one that will be writable unless -r is specified).
- DiskDescriptor.xml
-
Path to the DiskDescriptor.xml file with information about images.
Unmount a ploop device. Since a mounted ploop device consists of an image (or multiple images), a device, and (optionally) a file system mounted to a directory, one can refer to any of the above entities to specify what to unmount. The recommended way is to use DiskDescriptor.xml.
-
ploop umount
{
-d
device
|
-m
mount_point
|
DiskDescriptor.xml
|
image_file
}
- -d device
-
- Ploop device, e.g., /dev/ploop0.
- -m mount_point
- Mount point of a ploop device to unmount.
- DiskDescriptor.xml
- Path to the DiskDescriptor.xml file with information about images.
- image_file
-
Path to a mounted image file.
Replaces a ploop image by a different (but identical) one, on a running ploop device. Only a read-only image (e.g. a non-top one in a stacked configuration) can be replaced. An image to be replaced is specified by either one of level, UUID, or the current image file.
If a new image is not identical to the old one (i.e. its content differs) or not suitable for ploop in any other way (e.g. it is sparse, or resides on a file system not supported by ploop), the result is undefined.
-
ploop replace
{
-u
uuid
|
-l
level
|
-o
cur_image_file
}
[--keep-name ]
-i
image_file
DiskDescriptor.xml
- -u uuid
-
- A uuid of an image to be replaced.
- -l level
- A level of image to be replaced. A level is a distance of an image from the base delta.
- -o cur_image_file
- A current image file (the one to replace).
- -k, --keep-name
- A flag to keep the same image file name. If this flag is set, after the image is replaced, a new image_file is renamed to the old one (removing the old, now unused, image), so no modification to DiskDescriptor.xml is required.
- -i image_file
- A new replacement image.
- DiskDescriptor.xml
-
Path to the DiskDescriptor.xml file with information about images.
Resize a ploop image. Both online (i.e. when ploop is mounted and used) and offline resize is supported, and the tool can either grow or shrink both the ploop image and the underlying file system.
-
ploop resize
-s
size
DiskDescriptor.xml
- -s size
-
- Image size. If no suffix is specified, size is in sector units (one sector is 512 bytes). One can specify optional K, M, G or T suffix to set the size in kilo-, mega-, giga- or terabytes.
- DiskDescriptor.xml
-
Path to the DiskDescriptor.xml file with information about images.
Convert either ploop image format or version (but not both at the same time). Conversion can only be performed offline (i.e. image should not be in use).
-
ploop convert
{
-f
format
|
-v
version
}
DiskDescriptor.xml
- -f format
-
- Image format. See Image formats below.
- -v version
-
Image version, can be 1 or 2.
Check the internal consistency of (and possibly repair) a ploop image (or images). Note that image(s) to be tested should not be in use.
-
ploop check
[-u uuid]
DiskDescriptor.xml
- Check all the images in DiskDescriptor.xml up to the one
denoted by the uuid (or default top delta, if UUID is not
specified). Default built-in check options are used, and the ones
specified on the command line, if any, are ignored.
-
ploop check
[--force ]
[--hard-force ]
[--check ]
[--ro ]
[--silent ]
[--drop-inuse ]
[--raw ]
[--blocksize size]
[--repair-sparse ]
DiskDescriptor.xml
|
image_file
- -f, --force
-
- Force check even if image's dirty flag is not set.
- -F, --hard-force
- Same as -f, plus try to fix even fatal errors (can be dangerous).
- -c, --check
- Check for duplicated blocks and holes.
- -r, --ro
- Read-only access, do not modify image(s).
- -s, --silent
- Be more silent, only report errors.
- -d, --drop-inuse
- Drop image "in use" flag.
- -R, --raw
- Specifies that image_file is a raw ploop image.
- -b, --blocksize size
- Image cluster block size, in sectors (for raw images).
- -S, --repair-sparse
-
Repair sparse image(s).
Miscellaneous commands
- ploop info DiskDescriptor.xml
- When run without any options,
show information about disk space and inodes usage and limits on the
inner ploop filesystem, somewhat similar to
vzquota(8)
stat
or
show
commands.
- ploop info [-s ] [-d ] DiskDescriptor.xml
- Either one or both options can be used together. Option
-s
is used to show information about ploop device size, block size,
and format version.
Option
-d
is used to show a corresponding ploop block device, it available.
file.
-
ploop list
[-a ]
- Shows a list of running ploop devices (first column) and
their corresponding base images. With option
-a
it also shows a mount point (third column).
Create DiskDescriptor.xml file suitable for delta_file and put it into disk_dir.
-
ploop restore-descriptor
-f
format
[-b blocksize]
disk_dir
delta_file
- Read image header in case of ploop1 format or check raw image size and generate proper
DiskDescriptor.xml file. You can specify blocksize for raw images. If it's not specified
it will be choosen automatically - largest possible value between 32K and 1M. Raw image
size must be aligned to blocksize.
This command works only for base images. Snapshots are not supported.
Working with snapshots
Ploop snapshots is a mechanism for creating and managing instant states of a running file system. Creating a snapshot leads to creating a new empty ploop image which is layered on top of an old one, then all writes are ending up in the top image, and reads are falling through to a lower level. There can be up to 126) stacked ploop images (or snapshots). Online snapshot merging is also supported.
Snapshots are identified by a unique UUID. A snapshot can be mounted using ploop mount -u uuid command, see above.
Create a ploop snapshot.
-
ploop snapshot
[-u uuid]
DiskDescriptor.xml
- -u uuid
-
- Specify a uuid for a new snapshot. If option is not given, uuid is generated automatically. To generate uuid manually, one can use the uuidgen(1) utility. Note that UUID must be enclosed in curly brackets.
- Specify a uuid for a new snapshot. If option is not given, uuid is generated automatically. To generate uuid manually, one can use the uuidgen(1) utility. Note that UUID must be enclosed in curly brackets.
Merge a snapshot with its parent. That is, contents of the delta file corresponding to the snapshot is merged to a parent delta, then the file is removed. Parent snapshot UUID is lost (as it is replaced with the uuid specified). All snapshots having the lost one as a parent are updated to have the uuid as its parent.
-
ploop snapshot-merge
[-u uuid [-U uuid2] | -A]
[-n new_delta]
DiskDescriptor.xml
- -u uuid
-
- Specify a single snapshot uuid to merge. If this option is not specified, the top delta will be used.
- -U uuid2
- Together with -u uuid, specify that all snapshots in the range uuid...uuid2 are to be merged.
- -A
- Merge all snapshots down to base delta. If some snapshots have more than a single child, they will be impossible to merge.
- -n new_delta
-
If this option is set, instead of merging the child delta into its parent,
both the parent and the child deltas are merged into a newly created
file new_delta, which replaces the parent delta. Both deltas are
then removed.
Switch to the specified snapshot. This operation can only be performed while ploop is not running (i.e. is unmounted). The current top delta image will be removed.
-
ploop snapshot-switch
-u
uuid
DiskDescriptor.xml
- -u uuid
-
- Specify a snapshot uuid to switch to.
- Specify a snapshot uuid to switch to.
Delete the specifed snapshot. This operation can only be performed if the specified snapshot is not active. In case snapshot doesn't have any children, it will simply be removed. In case snapshot has a single child, it will be merged to that child. Deleting a snapshot that has multiple children is currently not supported (but can be performed manually in an iterative fashion).
-
ploop snapshot-delete
-u
uuid
DiskDescriptor.xml
- -u uuid
-
- Specify a snapshot uuid to be deleted.
- Specify a snapshot uuid to be deleted.
List available snapshots.
-
ploop snapshot-list
[-H ]
[-u uuid]
[-s ]
[-o field[,field...]]
DiskDescriptor.xml
- -H, --no-header
-
- Suppress displaying the header row. Usable for scripts.
- -u, --uuid, --id uuid
- Filter the output to a specified uuid.
- -s, --snapshot
- List in terms of snapshots. By default (i.e. without this option) the command lists all deltas, and top delta is marked as current. When this option is used, top delta is not listed, and the snapshot which is the parent of top delta is marked as current.
- -o, --output field[,field...]
-
Display only the specified fields. Possible fields are:
• uuid - snapshot's UUID;
• parent_uuid - snapshot's parent UUID;
• current - if this snapshot is the current one;
• fname - snapshot image file name.
Image copying
ploop copy is a mechanism of effective copying of a top ploop image with the help of build-in ploop kernel driver feature called write tracker. Write tracker is a feature that lets ploop copy to iteratively obtain a list of modified image blocks from the kernel. Two ploop copy processes are required for iterative top delta transfer. These are used by vzmigrate(8).
-
ploop copy
-s
device
[-F stop_command]
{
[-d file]
|
[-o output_fd]
[-f feedback_fd]
}
- This command enables the in-kernel write tracker for the specified ploop
device,
then sends all the data blocks from the top delta image to a pipe
specified by the output_fd argument (stdout, i.e.
1 by default), supposedly read by destination ploop copy,
or a file.
After that, it iteratively gets the list of the modified data blocks
from the kernel and sends those blocks again. After a number of iterations
(or when the list is empty), it executes the stop_command
(this could be vzctl stop or vzctl chkpnt) and does the last
iteration of sending the modified data blocks. Finally, it checks that the
data were not modified, error is returned otherwise.
If feedback_fd is specified, it is used to read back from the ploop copy receiving side. The feedback channel is currently used to wait for fdatasync(2) completion.
-
ploop copy
-d
file
[-i input_fd]
[-f feedback_fd]
- Reads the data blocks (provided by the source ploop copy)
from the file descriptor input_fd (stdin, i.e. 0
by default) and writes them to the file.
If feedback_fd is specified, it is used to send status back to the ploop copy sending side.
Ballooning
Since there is no online shrink support in ext4 file system, ploop internally uses a technique called "ballooning" as a work around to shrink its images.
Ballooning operation consists of inflating a special balloon file (invisible for ordinary users), loading fiemap info of the inflated balloon to the kernel, relocating blocks of the image file from the tail to the space specified by fiemap info, and truncating the tail of the image file. Result is the image file of a smaller size.
However, it is quite possible that inflated balloon file will only span blocks that were never touched before. Those will look like "not allocated" space from the kernel ploop point of view. In this case nothing will be relocated and nothing truncated.
So, if balloon operation succeeded, it's only guaranteed that a user of ploop device won't be able to consume more space than the initial block device size minus the size of the inflated balloon. On the other hand, if a user of block device used a lot of space on it, then freed the significant part of used space, balloon operation will result in significant truncate of image file.
All the ploop ballooning logic is hidden from the end user, so while a number of low-level commands exist for working with ploop ballooning, those are not needed and therefore are not documented here, except for a single command.
In a situation when a lot of disk space were freed on an in-ploop filesystem, use ploop balloon discard to optimize the ploop image size.
-
ploop balloon discard
[--automount ]
[--to-free size]
[--min-block min_size]
[--defrag ]
DiskDescriptor.xml
- Iteratively try to relocate and discard unused blocks from a ploop image,
reducing its size.
Note that ploop device and its inner file system should be mounted. If not, one can use --automount option to automatically mount ploop for the duration of the operation.
Option --defrag can be used to run a filesystem defragmentation utility (currently e4defrag2 on ext4 only) before the main operation.
Option --to-free can be used to specify a maximum disk space to be freed. In other words, stop the process once freed space exceeded requested size. Default is 0, meaning to try to free as much space as possible.
Option --min-block can be used to specify a minimum size of an extent to free. The smallest possible extent is 1 cluster (currently 1 MB), one can specify higher value to speed up the whole discarding operation.
Note that the same functionality is available by means of vzctl compact command.
Image formats
The following image formats are currently supported.- raw
- Raw format, with 1:1 mapping between the image file and the ploop device.
- ploop1, expanded
- Expanded format. The image will grow according to the needs of the underlying file system. This format is the default. Names 'ploop1' and 'expanded' are aliases.
- preallocated
-
This is the same as 'ploop1' or 'expanded', the only difference is
all the file blocks are allocated during creation.
EXIT STATUS
ploop exits with status 0 in case of successful execution. Any status greater than 0 signifies an error.- 1, SYSEXIT_CREAT
- Error creating a file.
- 2, SYSEXIT_DEVICE
- Error getting or opening a ploop device.
- 3, SYSEXIT_DEVIOC
- Error doing ioctl(2) on ploop device.
- 4, SYSEXIT_OPEN
- Error opening a file.
- 5, SYSEXIT_MALLOC
- Not enough memory (error from malloc(3), realloc(3), calloc(3), or posix_memalign(3)).
- 6, SYSEXIT_READ
- Error during read.
- 7, SYSEXIT_WRITE
- Error during write.
- 9, SYSEXIT_SYSFS
- Error reading from a sysfs file (usually under /sys/block/ploop...).
- 11, SYSEXIT_PLOOPFMT
- Corrupted ploop image detected.
- 12, SYSEXIT_SYS
- Other system error.
- 13, SYSEXIT_PROTOCOL
- Broken protocol (unexpected value received).
- 14, SYSEXIT_LOOP
- pcopy command can't finalize copying (frozen filesystem is changing).
- 15, SYSEXIT_FSTAT
- Error from stat(2), fstat(2), or statfs(2).
- 16, SYSEXIT_FSYNC
- Error from fsync(2) or syncfs(2).
- 17, SYSEXIT_EBUSY
- Can't continue, another operation is in progress.
- 18, SYSEXIT_FLOCK
- Error from flock(2).
- 19, SYSEXIT_FTRUNCATE
- Error from ftruncate(2) or truncate(2).
- 20, SYSEXIT_FALLOCATE
- Error from fallocate(2).
- 21, SYSEXIT_MOUNT
- Can't mount ploop image or file system.
- 22, SYSEXIT_UMOUNT
- Can't unmount ploop image or file system.
- 23, SYSEXIT_LOCK
- Locking failed (another operation in progress?).
- 24, SYSEXIT_MKFS
- Can't create file system.
- 26, SYSEXIT_RESIZE_FS
- Utility resizefs failed.
- 27, SYSEXIT_MKDIR
- Error from mkdir(2).
- 28, SYSEXIT_RENAME
- Error from rename(2).
- 29, SYSEXIT_ABORT
- Operation aborted.
- 30, SYSEXIT_RELOC
- Block relocation failed.
- 33, SYSEXIT_CHANGE_GPT
- Error resizing GPT partition table.
- 35, SYSEXIT_UNLINK
- Error from unlink(2).
- 36, SYSEXIT_MKNOD
- Error from mknod(2).
- 37, SYSEXIT_PLOOPINUSE
- Image is already in use.
- 38, SYSEXIT_PARAM
- Invalid parameter.
- 39, SYSEXIT_DISKDESCR
- Problem with DiskDescriptor.xml file.
- 40, SYSEXIT_DEV_NOT_MOUNTED
- Ploop image is not mounted.
- 41, SYSEXIT_FSCK
- Error from fsck(8).
- 43, SYSEXIT_NOSNAP
- Can't find specified snapshot UUID.